PIC24 -> UART -> IC MAX3471 -> RS-485 to RJ-45 converter -> RJ-45 to USB -> PC (running modbuspoll tool)Īt first, the Modbus read holding register function and write single register function is working. The motor setting like the angle, delay, start/stop, duty cycle, etc will be sent from PC using Modbus to PIC24. My task is to control a DC motor using micro PIC24. It specifically does NOT mean that a data item submitted for storage in a register has a value outside the expectation of the application program, since the Modbus protocol is unaware of the significance of any particular value of any particular register.Īn unrecoverable error occurred while the server (or slave) was attempting to perform the requested action.Anyone very experienced with Modbus & RS-485? This indicates a fault in the structure of the remainder of a complex request, such as that the implied length is incorrect.
#Modbus poll read error code#
If a request is submitted with a starting register of 96 and a quantity of registers of 5, then the request will fail with Exception code 0x02 "Illegal Data Address" since it attempts to operate on registers 96, 97, 98, 99 and 100, and there is no register with address 100.Ī value contained in the query data field is not an allowable value for the server (or slave). If a request is submitted with a starting register address of 96 and a quantity of registers of 4, then the request will operate successfully (address-wise at least) on registers 96, 97, 98, 99. For a controller with 100 registers, the PDU addresses the first register as 0, and the last one as 99. More specifically, the combination of reference number and transfer length is invalid. The data address received in the query is not an allowable address for the server (or slave). It could also indicate that the server (or slave) is in the wrong state to process a request of this type for example, because it is unconfigured and is being asked to return registered values. This may be because the function code is only applicable to newer devices and was not implemented in the unit selected. The function code received in the query is not an allowable action for the server (or slave).
#Modbus poll read error manual#
Please refer to the specific PLC user manual for further details.
#Modbus poll read error password#
The Multi-level Password can be invoked by creating a Password with an upper case " A" followed by seven numbers ( e.g., A1234567).
![modbus poll read error modbus poll read error](https://image.slidesharecdn.com/modbuspollmanual-141007004643-conversion-gate01/95/modbuspollmanual-22-638.jpg)
This allows Password protection while not locking the communication port to an operator interface. DirectLogic PLCs support Multi-level Password Protection of the ladder program. The Mode Switch of the PLC must be in the ( TERM) position in order for the C-more Panel to communicate with the PLC. Note: When using Automation Direct DirectLogic PLCs: 1. Note: The following Errors are generated from the designated PLC, monitored by the C-more Panel, and displayed on the panel's screen if active. Please refer to the PLC manufacturer's documentation for additional and up-to-date information. To see a link to the C-more Errors Table, which provides Error Codes specific to the C-more Panel, click the green text. These values, specific to the Modbus protocols, appear in the table below.
![modbus poll read error modbus poll read error](https://hitfreedownload.com/wp-content/uploads/2020/04/1488372194_modbus-poll-213x304-1-210x300.jpg)
The error message is displayed across the top of the panel screen.Įrror Code P499 shows any Errors that are generated by the connected PLC. The P499 Error Message includes a four-digit hexadecimal value displayed at the end of the message.